Installation Clearance - Mountain Series |
 |
|
printer friendly version

The Mt. Series oven should have
a minimum 1" (25mm) clearance to combustibles from all sides, and 14"
(356mm)
clearance to combustibles from the top.
If building materials will
contact the oven, they must be completely noncombustible. Please
note that standard drywall (or sheet rock) is considered a
combustible.
If the area directly above the doorway and
6" (152mm) to each side of the
doorway is to be covered with a facade, it must be of a non-combustible material.
1" (25mm) minimum side
clearance to combustibles. Non-combustible construction may
contact the oven and must then maintain 1" (25mm) clearance to combustibles.
Install this oven only on a
non-combustible floor which extends at least 36" (914mm) in front of
and 30" (762mm) to either side of the door.
All ovens equipped for stucco
application must have a clearance of 36" (914mm) to combustibles from all
sides and the top.